Correct settings for using the BlueForce APP

ATTENTION! if you have tried Bluetooth pairing or entered device/Bluetooth pairing codes you need to delete BlueForce Smart from the list of devices on your Smartphone/Tablet then restart it.
ATTENTION! If the BlueForce Smart is connected to your PC with the USB cable or with the Plug'n Go device, you must disconnect it and restart the force tester.

Excluding these two conditions, set up/verify your device with the following indications:

  • Verify that the operating system of the Smartphone/Tablet device is equal to or greater:
    • iOS: 9.0
    • Android: 5.0

  • Verify that the following settings are enabled on your device
    • Bluetooth / NFC / GPS
    • Network data connection or WI-FI

N.B. stand-by functions must be disabled

Start the Blueforce Smart APP and then make a test measurement with the force tester, after a few seconds the parameters and the graph will be displayed in your smartphone / Tablet, if the APP remains waiting without showing anything refer to the next paragraph
BlueForce APP does not receive measurements sent by the force tester - Using the NFC System

  • Carefully check the phone settings indicated in the previous paragraph
  • For Android devices it is advisable to clear browsing history
  • In some cases it is necessary to restart the Smartphone/Tablet

If the Bluetooth system is not compatible, it is advisable to use the NFC system that allows you to transfer the last test carried out by placing your device on the back of the BlueForce Smart, then:

  • Verify that the operating system of the Smartphone/Tablet device is:
    • iOS devices: from iOS 13.0 and devices from iPhone 7 onwar
    • Android devices: from o.s. 5.0 (N.B. in some cases it is necessary to clear the history of the Browser)

  • Activate the NFC function on the menu of the Smartphone/Tablet device
  • Make a test measurement with the force tester, then place your device on the back of the force tester and wait for the request / display of the measurement made (it is not necessary to start the BlueForce APP).
The force tester does not send the stored measurements to the software - Err2, Err3 Message

The errors reported on the display of the Blueforce / SpeedForce / BlueForce Smart, indicate the failure to connect with the PC or software:

  • Err 3 - Check that the USB cable is properly connected to the PC

  • Err 2 - The connected force tester does not communicate with the software (check the software setting here)
Setting the serial port on the software, force tester not detected, Err2

  • Turn on the PC and then connect the force tester with the USB cable or with the Plug'n Go device (if supplied).
  • N.B. if possible always use the same USB port of the PC.

  • Launch the BlueForce software, if you do not see pop-ups or warnings, the force tester is connected regularly and the serial port has configured itself automatically (use the SEND function to download the stored measurements, see here).

  • If you see the warning "serial port of pinch-force instrument not open" you need to configure the serial port in the software settings:
    • Verify that the force tester is connected with the USB cable or Plug'n Go device (if supplied)
    • Open the menu File -> Settings -> Serial Port -> Select the correct COM
    • N.B. if there is a black dot, click on the dot again
    • Exit the menu and re-enter to check the setting (black dot to the left of the COM port)
    • On the force tester use the SEND function to download the stored measurements, see here
The force tester does not send stored measurements to the software with the Plug'n Go (Bluetooth) device

Check that the mode of connection to the PC is set correctly, then enter the menu File -> Settings -> Serial Port -> Pc Connection Mode ->select Plug device.

N.B. If you have recently UPGRADED the force tester, without having sent the Plug'n Go Bluetooth device, communication with the software does not take place (contact Microtronics for updating the Plug'n Go device).
How to perform a test measurement with the force tester

  • Place the force tester on a flat surface, turn it on then place on the first free memory with the right button [e.g. 1 . . . .]

  • Make a strong pressure with the hand on the head of the force tester, then in 5 seconds the measurement is acquired [1 A . . .], then stored and simultaneously sent to the integrated Bluetooth / NFC system (if you use the BlueForce APP you can immediately consult the test on the Smartphone / Tablet device)

  • At the end the stored measurement is displayed with the number without dots [1    ]

How to send the measurements stored in the force tester to the software

  • Turn on the PC and then connect the force tester with the USB cable or the Plug'n Go (if supplied)

  • Start the BlueForce software and turn on the force tester, then with the left button, go to the FUNC menu, then with the right button look for the SEND function, then press the right button again for 2 seconds to send the measurements.

  • The SEND function will flash to indicate the "downloading of the measurements" to the software, (if the force tester indicates the Err2 message, see the paragraph "serial port setting" here)

  • The SEND function sends all measurements stored in the force tester to the software, completely emptying the memory
Software Updates and Operating Instructions

  • If you have an older version (e.g. 2.0) we recommend that you contact Microtronics

  • The latest software update (from ver. 3.0 onwards) is available in the download area

  • The complete software and operating instructions of Microtronics BlueForce can be downloaded here

  • Software for custom force testers from other brands should be requested at:  sales@microtronics.it

  • N.B. In case you need to replace/repair your PC, it is advisable to make a copy of the data/tests/customer archive in advance, see paragraph "Database backup" here
Calibration expired warning despite the force tester being regularly calibrated

  • It is necessary to download at least one test in the software so that it can recognize the regular calibration date, if the warning persists check these settings:

    • Check that the PC date is correct

    • If you have more force testers, another model may be configured (see BlueForce software -> settings menu -> Info -> Model), if different set the correct model.
Backup of stored measurements/customers (database)

If you want to re-install the software or to make a backup of the database (which contains customer and test data), we recommend that you make a copy of the database in an external memory:

  • In the BlueForce software enter the menu File -> Archive Manager -> Path, the "path" displayed is the default one where the database is stored (normally in the Documents folder)
  • Click on the path then select the external drive for storage (e.g. a USB memory)

Then (in case you need to install a new copy of the BlueForce software), just copy the content stored in the external memory in the same default location indicated in the software in the menu File -> Archive Management -> Path

In case you want to use the database from another location, you need to enter the menu File -> Archive Management -> Select Archive, and then select the database from the folder blueforce -> database
Changing Incorrectly Assigned Measurements

If measurements have been stored on an incorrect door (or referred to another regulation) it is necessary to transfer them to the correct door following this procedure:

  • Rename the door to another name (e.g. Wrong Entry Gate) using the edit menu (with the right button of the mouse)

  • Then create/insert the new door with the correct name (e.g. Entrance Gate)

  • From the "detail" area of the software drag the measurements (incorrectly associated) to the affected points of the new door

  • After this operation you can delete the previous incorrect door
Torna ai contenuti